PW

Max. discharge volume
220mL/min
Max. discharge pressure
2.0MPa

Description

Features

Safety

Three Types of Safety Features Offer Higher Level of Risk Control

Energy-Saving Characteristics

In ECO mode, the running status is constantly monitored to automatically reduce electricity usage when running at low pressure.. Previous models supplied constant electricity regardless of discharge pressure.

Ease-of-Use

Functions Common to All Models

Manual Operation

Stroke count control
Can be set in units of a single stroke.
Discharge amount control (PW only)
Can be set in units of 0.1mL/min.

External Operation/Stop Control

The pump can be turned ON/OFF via external signal input.

Alarm Output

Use with a level measurement instrument and a discharge amount checker to generate an alarm when an abnormality occurs.

Synchronized Pulse Control

A single pulse can be generated for a single pump action. The generated pulse can be entered to a second pump for synchronized operation.

  • Ex.)
    Control can be set so that in response to a single stroke at A, there are three strokes at B, two strokes at C, etc.

Signal Distribution

The connection below can be used without a signal distributor.

Pulse Signals

This unit can be connected in parallel to multiple pumps.

Analog Signal

This unit can be connected in parallel to multiple pumps.

Function of PW and PWT Only

  • *
    PWT can be set only if timer function is in use

Pulse Input Proportional Control

Pulse Frequency Dividing

The pump is operated one time per n times of input pulse.

Setting range
n=1~999

Pulse Magnitude

The pump is operated n times per each input pulse.

Setting range
n=1~999

Function of PWM Only

Analog Input Proportional Control

Automatic Operation

Receives an analog input signal (4 to 20 mA) and operates within the range of 0 to 300 strokes/min based on set values (target value and proportional band).

Function of PWT Only

Control of Timer Type

Interval Mode

Turns operation ON/OFF at a set interval.

ON time and OFF time can each be set to any single pattern in the range of 1 to 9999 minutes.

DAY Mode

Automatic operation starts every day at the same ON/OFF time set. Programs can be set in units of 1 minute within the range of 0:00 to 24:00 in a maximum of 9 patterns.

  • *
    Cannot be used in conjunction with WEEK mode.

WEEK Mode

Automatic operation starts every week at the same ON/OFF time and day set.

The program can be set to one pattern per each day of the week, and the ON time to a time within the range of 0:00 to 24:00 and the OFF time to a time within the range of 0:00 to 48:00 in units of 1 minute.

  • *
    Cannot be used in conjunction with DAY mode.