PZi

Max. discharge volume
540mL/min
Max. discharge pressure
0.3MPa

Description

Features

Enter Injection Amounts Directly and Select From Three Patterns of Injection Amount Settings

Set by stroke speed

Setting range
1 to 300 strokes/min (can be set to 1 stroke/min)

Set by discharge amount

Setting range
From 0.1 (maximum discharge amount for selected model)/mL/min (can be set to 0.1mL/min)

Set by percent

Setting range
1 to 100% (for a maximum stroke count (300 strokes/min) of 100%, can be set per 1%)

Free Power Supply

100 to 240 VAC (±10%) operation means you do not need to worry about voltage fluctuations at the site. This pump can be used at a variety of locations and for a variety of purposes.

Can Be Used With High Viscosity Liquids

Also use for polymer coagulant injections.

  • *
    Transfer of high viscosity liquids may not reach the prescribed maximum discharge volume. To transfer high viscosity liquids, please contact us for application support.

An Array of Wetted Part Materials to Handle a Wide Variety of Chemicals and Uses

Easy-to-Read Display Panel and Simple Operation Keys

Head Swivels in Three Directions to Fit the Mounting Location

Separated Head and Controller Convenient for Device Integration

Water-Resistant, Dustproof Construction

IEC standard
IP65 equivalent

Function of PZi4 and PZi8 Only

Analog Input Proportional Control

Injection amount (stroke speed: 0 to 300 strokes/min) can be set based on analog input signals (4 to 20 mA) from outside. Can be used to control pH or residual chlorine and a wide variety of other uses.

External Control of Stop Input

The pump stop signal can be entered externally to control switching the pump ON/OFF. Interlocked with a level or other measurement enables easy control of injection.

Pulse Input Proportional Control

Injection amount (1/9999 to 9999 strokes/pulse) can be set based on pulse input signals from outside. Interlocked with a pulse-emitting flowmeter to enable simple performance of a variety of automatic controls.

Function of PZi8 Only

Two-Point Control of Level Measurements

Control alarm display and generation, pump stop and other controls based on the amount of chemicals remaining in the tank.

Count Driving (Batch Injection Control) and Interval Driving (Timer Injection Control)

  • Count settings

    1~9999strokes(×1,×10,×100,×1000)

  • Interval settings
    ON time
    1~9999min
    OFF time
    1~9999min

Reviews